L.C.R. Bridge (PSAW-98)
Fully Solid state instrument, workable on 220 V 50 Hz or on 9 Volts Battery, useful for the wide range measurement of Resistance, Capacitance and Inductance.
Resistance Range : 0.01 Ohms to 1 Meg Ohms in seven ranges. Capacitance 2 PF to 110 MFD. Inductance 2 micro Henries to 110 Henry in seven ranges Accuracy ±1%, D-0.001 to 10Q=1 to 10.
Dimension 14"x9"x5˝"
See Enlarge
|
|
|
|
|
Dual Trace Oscilloscope ( PSAW-96A) It is a 20 MHz Dual Channel Oscilloscope that s ideal for, professionals as well as students undergoing technical studies. It is a rugged, light weight instrument that features a brijght, sharply defined trace on a 80 by 100 mm cathode ray tube. The internal trigger signal is ac coupled. An external triggering signal or an external Z-axis modulation signal can be applied via a front panel or rear panel connector and the source selector switch. The horizontal system provides calibration sweep speeds from 0.2s to 0.1 Micro S per division. For greater measurement accuracy a x5 magnifier circuit extends the maximum sweep speed to 20 ns per division. Special Features : Synchronisation of the signals from the two channels can be identified by a Red LED, marked as "READY", present on the right hand side top on the front panel.
Frequency Bandwidth
|
DC - 20 MHz |
Deflection Factor
|
5mV/div-10V x div x 5 |
Sweep Factor
|
0.2s-0.1s/div. ±5% |
Trigger Synchronization
|
Int, Alt, Line, Ext. TV. |
Vertical type
|
CH1, CH2, Alt, Chop |
Sweep Mode |
Auto, Trigger, Single time |
See Enlarge
|
|
|
|
|
Oscilloscope (PSAW-96) Fully Solid state workable on 220 volts 50 Hz. All supplies are stabilized for accurate and stable operation. Single beam with a band width DC to 10 MHz. The accurate triggering of time base enable clear and stable display on screen 8x8 cm. Vertical deflection can be selected for either A.C. or D.C. provision or attenuation in the input circuit, calibrated from 5 mV to 50V/cm.
Specifications : |
Band width |
Vertical D.C. to 10 MHz (3db) |
Sensitivity |
10mV/Cm Maximum |
Input Impedance |
1 M Ohm. |
Square wave calibration |
2 VP-P. |
Triggering |
Internal from vertical amplifier or external. |
Sweep Time Factor |
0.1 us/Div. 0.1s/div. ±5%. |
Horizontal Amplifier : |
Band width |
DC to 1 MHz. |
Display |
8x8 cm square |
Power requirement |
25 Watt 230 V 50 Hz. |
Dimension |
8"x5˝"x11" |
See Enlarge
|
|
|
|
|
Oscilloscope (PSAW -97)
This instrument is for college laboratory workable on 220 Volts. A.C. Vertical bandwidth 10 HZ to 2 MHz. Cathode Ray tube dimensions 8 cm. Sensitivity vertical 30 mV/Cm. Time base frequency 16 Hz to 50 KHz with Lock and Fine arrangement All controls for Focus, Intensity. X and Y shift are on rear panel. Built in arrangement for 50 Hz output for demonstration of lissageious figures
See Enlarge
|
|
|
|
|
Signal Tracer ( PSAW -99)
The instrument is used to locate faults in radio receiver. Workable on 220 Volt Hz. Probe 100 KHz to 30 MHz is provided to detect R.F. and I.F. Signal. The audible capability is upto 5 Watts. Complete with A.F./R.F. Probes and loudspeaker.
See Enlarge
|
|
|
|
|
Power Output Meter (PSAW -100)The instrument is to measure power directly across on load. The calibration is on a analogue meter and variable load can be selected by an band switch. The variation of load is 4, 8, 16, 32, 250, 600, 5000 ohms, range is 0-10 watts in two steps. 0 to 1 and 1 to 10 watts F.S.D., workable on 220 Volts, 50 Hz.
See Enlarge
|
|
|
|
|
V.T.V.M. ( PSAW -63) Workable on 220 V 50 Hz compiled in steel cabinet, rectangular meter 110x90mm.
Suitable for measurement of A.C. / D.C., Resistance 0-1000M. Ohms in seven ranges R.F. 0.50 Volts R.M.S. in 4 ranges.
D.C. Range |
: 1.5, 5, 15, 150, 500, 1500 FS-D |
A.C. Range |
: 1.5, 5, 15, 50, 150, 500, 1500 F.S.D. |
Resistance |
: 1K, 10K, 100K, 1M, 10M, 100M, 1000M. |
See Enlarge
|
|
|
|
|
Absorption Wave Meter (PSAW -132)
The instrument is to detect Radio frequency radiations. The wave length and strength can be known by tuning on L.C. Circuit. It consists of variable capacitor and two plugable inductors. Frequency covered is 1 MHz to 10 MHz
See Enlarge
|
|
|
|
|
Absorption Wave Meter ( PSAW -132 B)
Same as above with six coils 100 KHz to 100 MHz.
See Enlarge
|
|
|
|
|
Transistor Testor (PSAW -133)
Instrument is to test P.N.P. and N.P.N. transistors general purpose and low power. The indicator comprises an moving coil meter calibrated in gain or hfe. Socket provided for connecting transistor. Workable 220 V 50 Hz.
See Enlarge
|
|
|
|
|
Clamp ON Meter (PSAW -107F) Instrument is to measure alternating voltage and current without connecting the same, measurement is by induction effect in coil.
Measuring Range :
0 - 500 V A.C. |
0 - 500 Amps. A.C. |
D.C. and Resistance measure by leads. |
See Enlarge
|
|
|
|
|
Distortion Factor Meter (PSAW -202)
Instrument is measure unwanted distorted signal in an amplifier, by feeding pure sine wave and amplified signal passing through filters and distorted signal measured on meter in terms of percentage. The instrument consists of sine wave generator filter circuit and meter. Workable 220 V 50 H. The capability of this instrument is to measure distortion in audioable range 20 Hz to 20 KHz.
See Enlarge
|
|
|
|
|
Clamp ON Meter (PSAW -107F)
Instrument is to measure alternating voltage and current without connecting the same, measurement is by induction effect in coil.
Measuring Range : 0 - 500 V A.C.
0 - 500 Amps. A.C.
D.C. and Resistance measure by leads.
See Enlarge
|
|
|
|
|
Q Meter (PSAW -203)
The instrument is to measure ! (Quality factor) of an inductor. which is necessary to know when designing coils or transformer, measuring frequency is 1 KHZ or 10 KHZ. Measuring range is 0.1 to 100. Moving coil meter is used as indicator. Workable 220 V 50Hz. Balancing dial is directly calibrated in terms of Dimension : 14"x9"x5˝"
See Enlarge
|
|
|
|
|
Clamp ON Meter ( PSAW -107F)
Instrument is to measure alternating voltage and current without connecting the same, measurement is by induction effect in coil.
Measuring Range : 0 - 500 V A.C.
0 - 500 Amps. A.C.
D.C. and Resistance measure by leads.
See Enlarge
|
|
|
|