DESTRUCTOR INCINERATOR ElectricalElectrically or oil fired incinerator (only first two sizes can be supplied fully electrically operated and other sizes hall be supplies oil fired (LDO). These incinerators are suitable for inciration of pathological waste. Cost of chimney included.
a) 5-8 kg.
b) 10-15 kg
c) 25-35 kg.
See Enlarge
|
|
|
|
|
SYRINGE NEEDLE DESTROYERScientific research has discovered that used syringes and needles are very dangerous to human which can cause incurable disease like AIDS. Hepatitis and many more. Needle and syringe in a safe, Eco friendly, Cost effective manner. Needle & syringe in a safe, Eco friendly, Cost effective
Manner, after switching ON, insert the used needle to small hole provided and with in seconds the needle will be destroyed. Insert the syringe on the top of the machine in the big hole provided with a cutting blade, just pull the lever and syringe will be cut into two.
See Enlarge
|
|
|
|
|
OVERHEAD PROJECTORStreamlined body finished in various pastle colours. Projection head folding type, focusing by Rack-n- pinion. Illumination –600/650W-220V AC or 24V-250W halogen bulbs on step-down transformer with solid control light intensity and cooling system to projector overheating self-lubricating type motor, the stage temperature us maintained at 45° C approx. Interlocked with switch for lamp protection against voltage surges. Writing surface 250x250mm or 285x285 mm.
Complete with on-off switch, mains indicators, light intensity control switch cord plug & fuse etc accessories provided are transparent cellophane roll writing pen pack cleaning both venyle cover. Packed in a card board box with thermocole packing.
a) Single bulb low voltage 24V-250W Halogen through step-down transformer.
b) Double bulb low voltage system with two halogen bulbs 24V-250W through step-down transformer. The dual bulb system facilitates the switching over to second provided bulb instantly in case of damage of the running on with out disturbing contiPSAWity of discussion. Writing surface 250x250mm
c) Double bulb low voltage system with two Halogen bulbs 24V-250W through step-down transformer. The dual bulb system facilities switching over to second provided bulb system facilities switching over to second provided bulb instantly in case of damage of the running one with out disturbing contiPSAWity of discussion with writing surfacen285x285mm.
OPTIONAL:- Laser Pointer (Imported)
See Enlarge
|
|
|
|
|
OHP PORTABLE Folding typeFolding type smooth focusing with 3 element high definition focusing lens supported by picture sharpness compensator to achieve brilliant projection with optimum contrast. Equipped with two low voltage 24V 250W halogen bulbs with lever to instantly shift to second provided bulb in case of sudden failure of the running one. Mini turbo cooling fan thermal cut for safety. Writing surface 285x285mm. Supplied in molded luggage case. See Enlarge
|
|
|
|
|
PROJECTION SCREEN With Metallic StandMetallic, sturdy folding, portable with collapsible tripod stand. Housing equipped with automatic spring roller system. Screen size:
Screen size:-
| Projection Screen (Tripod Model) Deluxe |
180x230cm |
Projection Screen (Tripod Model) Deluxe |
132x178cm |
Projection Screen (Tripod Model) Deluxe |
150x150cm |
Projection Screen (Tripod Model) Deluxe |
125x125cm |
MULTIMEDIA PROJECTION SCREEN ( With Metallic Stand)
Projection Screen (High Gain) Tripod Model |
180x230cm |
Projection Screen (High Gain) Tripod Model |
132x178cm |
Projection Screen (High Gain) Tripod Model |
150x150cm |
Projection Screen (High Gain) Tripod Model |
125x125cm |
See Enlarge
|
|
|
|
|
PROJECTION SCREEN Wall HangingFolding type in metallic case wall hanging arrangement provided.
Screen Size:-
| Projection Screen (Wall and Ceiling Model Deluxe) |
180x230cm |
Projection Screen (Wall and Ceiling Model Deluxe) |
132x178cm |
Projection Screen (Wall and Ceiling Model Deluxe) |
150x150cm |
Projection Screen (Wall and Ceiling Model Deluxe) |
125x125cm |
MULTIMEDIA PROJECTION SCREEN (wall hanging)
Projection Screen (High Gain) |
180x230cm |
Projection Screen (High Gain) |
132x178cm |
Projection Screen (High Gain) |
150x150cm |
Projection Screen (High Gain) |
125x125cm |
See Enlarge
|
|
|
|
|
PROJECTION SCREEN EconomicScreen Size:-
a) 120x130cm.
b) 130x178cm.
See Enlarge
|
|
|
|
|
BIOLOGICAL SAFETY CABINETThe cabinet are fabricated out of thick board duly laminated sheet clad. The work table is made of heavy gauge stainless steel sheet and is fitted with U.V. Germicidal light, static pressure manometer, exhaust system (suitable for 6 feet duct) and virus burn out unit. Side panels are made of thick transparent flexi glass duly framed. The unit is fitted with pre-filter and HEPA filter. Air is drawn through pre-filter and is made to pass through highly effective HEPA (High efficiency particular air) filters having efficiency retaining all air borne particle of size 0.3 micron and large. Using a dynamic balancing machine, the blower and motor assembly is statically and dynamically balanced. Motor of 1/5 H.P. Capacity operates with minimum noise level. The working area is illuminated by florescent lighting fitted to the unit. In addition to the above features of a standard vertical laminar flow bench, the “LABOTECH “ Bio-safe cabinets have arrangements for recalculating a part of the air thus creating highest level of clean air. The unit is also convertible to the conventional vertical laminar flow bench with download air flow by fitting the sliding front door upwards. Air is sucked through the pre-filter and the excess air is thrown out the top through a HEPA filter of size 1’x1’x6”. Supplied with glove ports and gauntlets, HEPA filter, pre-filter, U.P. light and fluorescent light.
Working size |
2’x2’x2’ |
3’x2’x2’ |
4’x2’x2’ |
6’x2’x2’ |
Size of HEPA Filter |
2’x2’x6” |
3’x2’x6” |
4’x2’x6” |
3’x2’x6” |
No. of HEPA Filter |
1 |
1 |
2 |
2 |
Illumination |
1x20W |
1x20W |
1x30W |
1x30W |
OPTIONAL:-
i) Virus burn out unit
ii) Exhaust Ducting (Per running feet)
iv) Gas Burner
See Enlarge
|
|
|
|
|
GARMENT STORAGE CABINET Vertical FlowSelf standing providing down flow air to clean room Garments. Recommended in clean room
For storage of materials. Suitable for pharmaceuticals, Hospital and O/T, Electronic industry
Etc. Supplied complete with HEPA Filter & pre filter, MOTOR Blower etc. But with static
Pressure manometer, U.V. Germicidal light, Fluorescent light.
Working Area
|
3’x2’x5’ |
4’x2’x5’ |
| Size of HEPA Filter |
3’x1 ½’ x6” |
4’x1 1/2 ‘x6” |
| No. of HEPA Filter |
1 |
1 |
| No of pre Filter |
1 |
2 |
a) Whole Cabinet made of commercial board & laminated with sun mica.
b) Whole Cabinet made of cold rolled steel sheet duly powder coated inside & outside for longer life & durability.
OPTIONAL:- Exhaust Ducting per running ft.
See Enlarge
|
|
|
|
|
MATERIAL STORAGE CABINET Vertical FlowSelf-standing providing down flow air to clean room garments . Recommended in clean room for storage of material. Suitable for pharmaceuticals, Hospitals and O/T, Electronic industry etc. Supplied complete with Hepa filter & pre filter, Motor Blower, Static pressure manometer, U.V. Germicidal light, Fluorescent light and shelves.
Working Area |
3’x2’x5’ |
4’x2’x5’ |
Size of HEPA Filter |
3’x1 ½ x6” |
4’x1 ½’x6” |
No. of HEPA Filter |
1 |
1 |
| No. of Pre Filter |
1 |
2 |
No. of Shelves |
3 |
3 |
A) Whole Cabinet Made of commercial board & laminated with sun Mica.
B) Whole Cabinet made of cold rolled steel sheet duly powder coated inside & outside for longer life & durability.
OPTIONAL:-
a) Extra Shelves.
b) Exhaust Ducting per running ft.
See Enlarge
|
|
|
|
|
HORIZONTAL LAMINAR AIR FLOW CABINETLaminar flow principle involves double filtration of air through coarse pre-filter (up to 5 microns)
And HEPA filter (down to 0.3 microns) for filtration of biological and particulate contaminants. A Constant uni-directional air flow is drawn from atmosphere and passed through pre and hepa filters
On the work surface. Fabricated out or reinforced by board which is clad in from outside in laminated Sheet and inner laminated sheet and inner exposed areas are finished in epoxy paint. Table top covered with non glaring laminated sheet or stainless steel sheet. Side panels are fixed and are made out of transparent acrylic sheet. The front door is folding type and made of thick acrylic sheet. (Optional) Stand is built in type or detachable.
Blower unit has AUE or equipment motor and is dynamically balanced with minimal sound & vibration level. Fluorescent lighting is also provided. A Suitable UV tube is provided for sterilization. An acrylic block type manometer to measure static pressure in the chamber has been installed. Two ways gas tap for gas line has also been provided.
|
(A) |
(B) |
(C) |
(D) |
(E) |
Working Chamber |
2’x2’x2’ |
3’x2’x2’ |
4’x2’x2’ |
6’x2’x2’ |
8’x2’x2 |
SIZE OF HEPA Filter |
2’x2’x6” |
3’x2’x6” |
4’x2’x6” |
3’x2’x6” |
4’x2’x6” |
No. of HEPA filter(Supplied with main Unit) |
1 |
1 |
1 |
2 |
2 |
No. of Filter |
1 |
1 |
1 |
2 |
2 |
Illumination |
1x20W |
1x20W |
2x20W |
2x40W |
4x40W |
U.V. Germicidal Light |
1x1 ½ feet |
1x1 ½ feet |
1x3 feet |
2x3 feet |
2x3 feet |
A) Whole Cabinet made of commercial board & laminated with sun mica.
B)Whole cabinet made out of stainless sheet duly smooth polished enhances the life of cabinet.
See Enlarge
|
|
|
|
|
HORIZONTAL LAMINAR AIR FLOW CABINET Table Top ModelThese equipment are also horizontal laminar air flow cabinets. These are table top model and not floor mounted. These can be easily placed on exiting laboratory platform. However if required, tubular stand can be provided for these laminar flow cabinet & for its work table, of these equipment are to used as floor mounting design. Supplied with Static pressure manometer, U.V. Fluorescent light, Cock for gas & air.
|
(A) |
(B) |
(C) |
(D) |
(E) |
Working Chamber |
2’x2’x2’ |
3’x2’x2’ |
4’x2’x2’ |
6’x2’x2’ |
8’x2’x2 |
SIZE OF HEPA Filter |
2’x2’x6” |
3’x2’x6” |
4’x2’x6” |
3’x2’x6” |
4’x2’x6” |
No. of HEPA filter(Supplied with main Unit) |
1 |
1 |
1 |
2 |
2 |
No. of Filter |
1 |
1 |
1 |
2 |
2 |
Illumination |
1x20W |
1x20W |
2x20W |
2x40W |
4x40W |
U.V. Germicidal Light |
1x1 ½ feet |
1x1 ½ feet |
1x3 feet |
2x3 feet |
2x3 feet |
C)Whole Cabinet made of commercial board & laminated with sun mica.
D) Whole cabinet made out of stainless sheet duly smooth polished enhances the life of cabinet.
OPTIONAL:- Tubular Stand
See Enlarge
|
|
|
|
|
VERTICAL LAMINAR AIR FLOW CABINETDetails same as above BDI-170 with laminar flows down vertically form top to wards the work table. Supplied complete with static finish Mica table top. Transparent front door (5m.m). Static pressure manometer. Built in U.V. Germicidal light & fluorescent light and Cock for gas, air or vacuum line.
|
(A) |
(B) |
(C) |
(D) |
(E) |
| Working Area |
2’x2’x2’ |
3’x2’x2’ |
4’x2’x2’ |
6’x2’x2’ |
8’x2’x2 |
SIZE OF HEPA Filter
|
2’x2’x6” |
3’x2’x6” |
4’x2’x6” |
3’x2’x6” |
4’x2’x6” |
| No. of HEPA filter(Supplied with main Unit) |
1 |
1 |
1 |
2 |
2 |
No. of pre Filter
|
1 |
1 |
1 |
2 |
2 |
Illumination
|
1x20W |
1x20W |
2x20W |
2x40W |
4x40W |
| U.V. Germicidal Light |
1x1 ½ feet |
1x1 ½ feet |
1x3 feet |
2x3 feet |
2x3 feet |
E) Whole Cabinet made of commercial board & laminated with sun mica.
F) Whole cabinet made out of stainless sheet duly smooth polished enhances the life of cabinet.
See Enlarge
|
|
|
|
|
FUME HOODFabricated out of thick wooden board. It is designed so as to throw-out all toxic/harmful vapors & fumes thus protecting costly instrument and the persons working in the lab. Outer is finished with sunmica and inner epoxy painted. Working table top is acid/alkali resistant and a small wash basin with connections provided for inlet and outlet of water. The front door moves vertically up and down with concealed counter balanced weights. The unit is fitted with fluorescent light and a gas cock for gas/air supply. The front facing panel is fitted with 15/5 Amp socket with switches for exhaust system and fluorescent light. To work on 220/230 volts A.C. Supply.
| |
(A) |
(B) |
(C) |
(D) |
| Working Chamber size:- |
3’x2’x2’ |
4’x2’x2’ |
5’x2’x2’ |
6’x2’x2’ |
OPTIONA:-
I) High CFM exhaust system (for duct exceeding 10 feet length)
iii) S.S. Lining on work bench.
iv) PVC Fume Duct (per ft.)
See Enlarge
|
|
|
|
|
AIR CURTAINS Very useful to create curtain of air between Air-conditioned and clean room to adjoining room. Widely used in various applications in industry, Hospital, Hotels, and Showroom etc.
Door |
Width |
600 |
mm |
900
|
mm |
1200
|
mm |
1500
|
mm |
1800 |
mm |
See Enlarge
|
|
|
|