Severity: Warning
Message: Trying to access array offset on value of type null
Filename: controllers/Products.php
Line Number: 203
Backtrace:
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 203
Function: _error_handler
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
Severity: Warning
Message: Trying to access array offset on value of type null
Filename: controllers/Products.php
Line Number: 204
Backtrace:
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 204
Function: _error_handler
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
Severity: Warning
Message: Trying to access array offset on value of type null
Filename: views/product_detail_view.php
Line Number: 30
Backtrace:
File: /home2/psawcmdw/public_html/application/views/product_detail_view.php
Line: 30
Function: _error_handler
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 210
Function: view
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
FRICTION IN PILE LINES APPARATUS : PSAW-713FM
The Set-up consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
EXPERIMENTS:-
·
To
determine the losses due to fiction in pipes
·
To
determine the friction factor for Darcy Weis back equation
UTILITIES REQUIRED: –
·
Water
Supply & Drain
·
Electricity
Supply: Single Phase, 220 VAC, 0.5 kW
TECHNICAL SPECIFICATION: –
·
Pipes
(2 Nos.) : Material GI of ½ “ & 1” Diameter
·
Pipe
Test Section : Length 1 m
·
Water
Circulation : FHP Pump, Crompton / Sharp make
·
Flow
Measurement : Using Measuring Tank with Piezometer,Capacity 25 Ltrs.
·
Sump
Tank : Stainless Steel, Capacity 50 Ltrs.
·
Stop
Watch : Mechanical / Electronic
·
Control
Panel : On / Off Switch, Mains Indicator etc.
The whole Set-up is well designed and arranged in a good quality painted Structure.