KAPLAN TURBINE TEST SETUP Psaw India

KAPLAN TURBINE TEST SETUP

Product Cat # PSAW-902HM

QTY


KAPLAN TURBINE TEST SETUP

Description

KAPLAN TURBINE TEST SETUP  : PSAW-902HM

 

Kaplan Turbine is an axial flow reaction Turbine named in honor of Dr. B. Kaplan, a Gennan Engineer. This turbine is suitable for low head. The power produced by a turbine is proportional to QH. As the head (H) decreases the J discharge (Q) must increase to produce the same power. The present Set-up consists of a scroll casing housing a runner. Water enters the turbine through the stationary guide vanes and passes through the runner axially. The runner has a hub and airfoil vanes, which are mounted on it. The water is fed to the turbine by means of Centrifugal Pump. The runner is directly mounted on one end of a central SS shaft and other end is connected to a brake arrangement. A transparent hollow cylinder made of acrylic is fitted in between the draught tube and the casing for observation of flow on to the airfoil vanes. This runner assembly is supported by thick cast iron pedestal. Load is applied to the turbine with the help of this brake arrangement so that the efficiency of the turbine can be calculated. The Set-up is supplied with control panel. A draught tube is fitted on the Outlet of the turbine. The Set-up is complete with guide mechanism. Pressure and Vacuum Gauge are fitted at the Inlet & Outlet of the turbine to measure the total supply head on the turbine.

 

EXPERIMENT:-

·         To study the operation of a Kaplan Turbine

·         To determine the Output Power of Kaplan Turbine

·         To determine the Turbine Efficiency

 

UTILITIES REQUIRED:-

·         Water Supply and Drain.

·         Electricity 15 kW, 440V AC, Three Phase

 

TECHNICAL SPECIFICATIONS:

 

MODEL                                 

HM 902 (1.33 HP)     

HM 902 (5 HP)

 

Output Power

1.33 HP / 1 Kw

5 HP / 3.75 Kw

Discharge

1500 LPM (Approx.)

5000 LPM (Approx.)

Supply Head

5 m

5 m

Rope Brake Dynamometer

Dia 200 mm

Dia 300 mm

Sump Tank

Capacity 300 Ltrs.

Capacity 600 Ltrs.

Water Circulation Centrifugal Pump

Capacity 7 HP, Three Phase

Capacity 20 HP, Three Phase

Speed

1500 RPM (approx.)

Runner           

With adjustable Curved Vanes

 

Discharge Measurement

Pitot Tube with Manometer

Control Panel

Star/Delta Starter, Mains Indicator, MCB for overload protection


  

The whole set-up is well designed and arranged in a good quality painted structure.