Severity: Warning
Message: Trying to access array offset on value of type null
Filename: controllers/Products.php
Line Number: 203
Backtrace:
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 203
Function: _error_handler
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
Severity: Warning
Message: Trying to access array offset on value of type null
Filename: controllers/Products.php
Line Number: 204
Backtrace:
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 204
Function: _error_handler
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
Severity: Warning
Message: Trying to access array offset on value of type null
Filename: views/product_detail_view.php
Line Number: 30
Backtrace:
File: /home2/psawcmdw/public_html/application/views/product_detail_view.php
Line: 30
Function: _error_handler
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 210
Function: view
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
AIR CONDITIONING TRAINER GENERAL CYCLE TYPE : PSAW-204RA
The unit
consists of ducting fitted with various air conditioning components. Airflow is
generated by an axial flow fan and in the airflow, heaters, cooling coil and
steam humidifier connection is provided. Cooling circuit consists of a hermetic
compressor; air cooled condenser, thermostatic expansion valve and evaporator
(i.e. cooling coil). Measurements of various parameters Torn cooling cycle and
heating cycle are provided and students can easily visualize and understand the
basic principles of air conditioning.
SPECIFICATIONS:
1.
Cooling
circuits – It consists of:
a)
Hermetic
compressor, having the capacity of 2/3 ton of refrigeration (approx.) using
R-22 refrigerant.
b)
Rotameter
for liquid refrigerant flow measurement.
c)
Pressure
gauges for high and low pressure.
d)
Prescott
(i.e. high and low pressure cut-out).
e)
Thermometers
for temperature measurement at various points in the cycle.
f)
Energy
meter for compressor input measurement.
g)
Condensate
measuring arrangement.
2.
Heating
Circuit – Air heaters with input control provided with energy meter for input
measurement. Maximum heating capacity 1 Kw.
3.
Steam
generator and injector for humidification of air. All above components are
connected to a duct of size 200mm. X 200mm. in which airflow is generated by
axial flow fan.
4.
Anemometer
for measurement of air velocity, (range 0-15 m/sec. Following experiments can
be conducted on the unit
a)
Cooling
of atmospheric air.
b)
Heating
of atmospheric air.
c)
Humidification
of atmospheric air.
d)
Dehumidification
and heating of atmospheric air.
Cooling coil acts as dehumidifier at reduced airflow.
SERVICES REQUIRED:
·
440
V, 15 A, 3 Phase supply with earthing connection.
· Floor space area about 3 m. X 2 m.