Deprecated: Required parameter $case follows optional parameter $productId in /home2/psawcmdw/public_html/application/models/Default_model.php on line 19

Deprecated: Required parameter $sub follows optional parameter $productId in /home2/psawcmdw/public_html/application/models/Default_model.php on line 19

A PHP Error was encountered

Severity: Warning

Message: Trying to access array offset on value of type null

Filename: controllers/Products.php

Line Number: 203

Backtrace:

File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 203
Function: _error_handler

File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Trying to access array offset on value of type null

Filename: controllers/Products.php

Line Number: 204

Backtrace:

File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 204
Function: _error_handler

File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once

AIR CONDITIONING TRAINER WINDOW TYPE Psaw India

AIR CONDITIONING TRAINER WINDOW TYPE

Product Cat # PSAW-205RA

QTY


AIR CONDITIONING TRAINER WINDOW TYPE

Description

AIR CONDITIONING TRAINER WINDOW TYPE  : PSAW-205RA

 

Window air conditioner is becoming now a day’s necessity. The unit demonstrates the application of window air conditioner & evaluation of its performance. It consists of a small room to which a small air conditioner is connected the room is provided with a transparent front cover with a heater inside to simulate heat load in the room. Various measurements are provided so that performance of system that is COP of system, actual & theoretical cooling capacity of system & power consumption of unit with different load conditions.

 

SPECIFICATIONS:

1.      Compressor – Hermetically sealed, Kirloskar make, having the capacity of 1/10 ton of refrigeration using R-12 refrigerant to keep room temperature between 20 to 30 c.

2.      Condenser – Finned tube type, with forced air flow over the tubes,

3.      Capillary tube of matched length as expansion device.

4.      Evaporator – Finned tube type with forced air flow,

5.      Room – 0.6 X 0.7 X 0.7 m. height, provided with transparent front wall. A heater with input control is provided inside the room. Which simulates different load conditions.

6.      Measurements and Controls

a)      H.P. / L.P. Pressure gauges

b)      Digital temperature indicator to measure the temperatures at various points.

c)      Energy meters to measure input to compressor & heater.

d)     High and low pressure cutout.

e)      Thermostat to put off the compressor at set room temperature.

f)       Necessary switch for electrical components.

 

SERVICES REQUIRED:

·         Floor area of 2m X 1 m.

·         230V, 15AC stabilized supply with earthing connection.