Severity: Warning
Message: Trying to access array offset on value of type null
Filename: controllers/Products.php
Line Number: 203
Backtrace:
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 203
Function: _error_handler
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
Severity: Warning
Message: Trying to access array offset on value of type null
Filename: controllers/Products.php
Line Number: 204
Backtrace:
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 204
Function: _error_handler
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
Severity: Warning
Message: Trying to access array offset on value of type null
Filename: views/product_detail_view.php
Line Number: 30
Backtrace:
File: /home2/psawcmdw/public_html/application/views/product_detail_view.php
Line: 30
Function: _error_handler
File: /home2/psawcmdw/public_html/application/controllers/Products.php
Line: 210
Function: view
File: /home2/psawcmdw/public_html/index.php
Line: 315
Function: require_once
MECHANICAL HEAT PUMP TRAINER : PSAW-209RA
Heat Pump is a
device to pump heat from one source to another. The heat obtained by heat pump
is more than that could be obtained by direct electrical heating. The apparatus
consists of refrigeration system with water cooled shell and coil type
evaporator and condenser.
SPECIFICATIONS:
1.
Compressor
– Hermetically sealed compressor using R-12 refrigerant, having capacity 0.3
tons of refrigeration. Condensing pressure – max. 15 Kg/cm2 (Actual pressures
will depend upon working conditions).
2.
Condenser
– Shell and coil type with continuous water flow arrangement.
3.
Evaporator
– Shell and coil type with continuous water flow arrangement.
4.
Expansion
Valve – Internally equalized thermostatic expansion valve.
5.
Measurements
–
a)
Rotameter
for condenser & evaporator water flow rate measurement.
b)
Rotameter
for liquid refrigerant flow measurement.
c)
Pressure
gauges for condensing and evaporating pressure – 2 Nos.
d)
Thermometer
for refrigeration cycle & water temp, measurement – 7
e)
Wattmeter
for compressor input measurement.
f)
Ammeter
for compressor current measurement.
6.
Controls
–
a)
HP/LP
cut out for compressor.
b)
Overload
protector for compressor.
c)
Gate
valve to control water flow rates.
d)
Necessary
switches and fuse.
A technical manual is accompanies the unit.
SERVICES REQUIRED:
·
Floor
surface area – 2m, X 2m. X 1.5m. height.
· 220V. 15Amp. Single Phase Stabilized power supply.